왕수 ( Aqua regia ) ( Aqua regia or aqua regis (Latin for royal water or king's water) is a highly corrosive, fuming yellow or red solution, also called nitro-hydrochloric acid. The mixture is formed by freshly mixing concentrated nitric acid and concentrated hydrochloric acid, usually in a volumetric ratio of 1:3 respectively. It was named so because it can dissolve the so-called "royal metals," or noble metals, g..
[BBC NEWS] Leukaemia cells 'killed quicker' The team examined leukaemia cells before (left) and after treatment Leukaemia cells 'killed quicker' The team examined leukaemia cells before (left) and after treatment Scientists have claimed to have found a way of killing leukaemia cells quicker and more effectively. The Simon Flavell Research Laboratory in Southampton used a compound from the common gypsophila plant to break down the membrane..
AKTA purifier UV check 본기기는 CU-950 , pH/C-900 , UV-900 , P-900이 합쳐져 있다. 일체형인 본기기의 가운데를 차지하고 있는 UV kit이다. 2010 5 30일 평소와 다른 UV wavelength의 저하와 starting mode에서의 calibration의 failed 를 인지하고 점검을 시도하였다. 오른쪽의 다이얼을 돌리면 여러가지 메뉴가 나타나는데 이중 check란에 위치시키고 ok를 누른다. 여기서 ok누른다.. 그리고 나서 다시 다이얼을 돌리면 UV lamp의 지금까지의 사용시간과 wavelength의 intensity를 확인할수 있다. 일반적인 UV lamp의 수명은 4000h 이기 때문에 비교하면 남은 수명을 대략적으로 짐작할수 있다. intensity의 경우 파장별로 %로 표시가 되..
NMR operation 일시 : 2010 5 26 일 장소 : 서울대 기초과학공동기기원 2일간의 이론교육을 끝내고 금일 실습기회를 가졌습니다. 친절한 조교님 덕에 사고(?) 없이 무사히 끝냈네요ㅋ [1] Sample 0.2mmol 농도의 Sample 준비 ( 시료를 녹인 검액은 tube bottom에서부터 상부 3Cm정도 이상으로 담아준다,shimming 일정하게 하기위함) [2] Operation 1. Computer On 2. Log-in , PW 입력 3. TOPSCAN 실행 4. lock signal window 실행 ( 창이 뜨지 않는 경우 상부 입력바의 버튼을 눌러준다) 5. File-New 6. Name ( folder name ) , EXPNO ( sub-folder , sample갯수로 지정하면 좋다 ) 입력 ..
2010 4 29 Journal club 발표용 J Chromatogr A. 2010 Apr 30;1217(18):3044-52. Epub 2010 Mar 4. Separation of alpha-cyclohexylmandelic acid enantiomers using biphasic chiral recognition high-speed counter-current chromatography. Tong S, Yan J, Guan YX, Fu Y, Ito Y. Department of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310027, China.
Column scale-up During many instances, it may be necessary to increase the size of a chromatography column in order to increase the production capacity of a process. By doing so will require a scale-up of the column to a suitable size for the job. The most straightforward way to scale up a column is to maintain the same column length and to increase the cross-sectional area to maintain a constant ratio of unkno..
Peak shape of HPLC-ELSD 최근 HSCCC를 이용한 AT의 분리에 있어서 단일 성분으로 예상됨에도 불구하고 큰 피크의 모양이 비 대칭이고 조그마한 다른 피크 ( valley peak )가 보여서 왜 그런가 하고 찾아보았다.. 물론 위 그림은 HSCCC-ELSD 의 그림이고 아래 답변은 HPLC-ELSD 에 대한 답변이나, 문제는 ELSD에 있다고 판단된다. Sometime, the ELSD detector can give the peak shape like that, depending on the flow rate and droplets size distribution. If the nebulizer doesn't function well, some large droplets travel later than most fine dr..
Relative Standard Deviation (RSD) Definition of relative standard deviation : Same as coefficient of variation. The standard deviation is a measure of how precise the average is, or how well the numbers in a sequence agree or relate to each other. It is a measure of random error-the error not easily controlled, and is calculated as the sum of the differences between the numbers in a series from the average of those numbers divid..